China Steel Sumikin Steel Corporation (CSVC)
vi

China Steel Sumikin Steel Corporation (CSVC)

Publish: 6/15/2017 Viewed: 3075

(TECHPRO) -Project: "Building security gate system - electronic time attendance and security camera" of China Steel Sumikin Steel Corporation (CSVC)

Project location: My Xuyen Industrial Zone A2 - Ba Ria - Vung Tau

Project Owner: China Steel Sumikin Steel Corporation (CSVC)

Contractor: TRUNG LOI COMPANY

Commencement date: 18/08/2012

Completion Date: 02/07/2013

Describe project

Objective of the project

On September 08, 2011, at China My Sumitin Industrial Zone, Tan Thanh District, Ba Ria Vung Tau Province, China Steel Sumikin Vietnam Joint Stock Company (CSVC), a joint venture between China Steel and Nippon Steel Sumitomo Metal, The construction of the CSVC steel sheet plant started.

The CSVC steel plate plant, built on an area of 109ha, with a total investment of US $ 1.15 billion, is expected to come online in 2013, with a capacity of 1.2 million products per year.

With the scale of the project, when the factory initially came into operation, the number of workers was up to 1000 people, it was necessary to have a management system in place to operate the plant smoothly and smoothly to achieve high efficiency in The management as well as the timekeeping report.

Therefore, the Access Control System will be a system of equipment that uses process-based control systems (DSC) to prevent a single component fault that causes Trouble of the whole system. The system has the advantages of "ease of use" and incorporates interactive programming (Q & A). All scheduled programs will function when all functions of the system are fully activated without affecting the operation of the system.

The factory entrance and exit management system is designed on the principle of controlling the distribution of traffic of people entering the factory.

* Barrie system incorporates Access Control to control the gateway to the factory.

* The Tripod Turnstile security gate system controls employee entry and exit times.

* Access control system and time attendance equipment in the plant area.

* Magnetic card printers are used to distribute cards to employees and contractors.

- Employees of the factory, working in shifts.

- Leadership of the company, working mainly in administrative hours

- Security guards and technicians

- The visitors to visit.

- Apply for card printing & card issuance for new employees, contractors, ...

The system consists of a server, workstation and two control centers that connect the plant's LAN in peer-to-peer mode and the door controls and some other devices to control the inlet of the plant.

Principles of managing and controlling the card system include:

- Time attendance control for all employees of the plant through IDTECK / Korea access control system using biometric fingerprint technology, or RFID tag, PIN code combined with security door. Tripod Turnstile. Using 05 lanes to meet the number of employees to plant up to 1000 people. Entrance controls at entry and exit points are recorded. Areas such as the entrance of the factory when the customers come to the transaction are issued cards, convenient in management.

- Access management to functional departments with fingerprint reader, card, PIN. Only valid fingerprints, cards, and PINs are allowed in and out.

- With the operation of the plant, the design system ensures high stability in both modes:

Online mode: In this mode, data from readers is updated regularly on the central computer.

Offline mode (ofline): In case of trouble or shut down the central computer, data center cable, power failure ... in offline mode data from the reader is saved. Storage on the Controller has a backup battery power supply and as soon as the computer or bus is repaired, automatic data transfer to the hub. This is a very important feature in the process of using it does not affect production and especially important in emergencies such as fire, data cable is broken ... will be very dangerous for Lives and affects the cure if the offline mode.

- The operating status of the readers should be installed according to the time and the requirements of each area. In some cases, the authorized person can turn off the reader's working status from the graphical display. Overtime, overtime, Sundays, Saturdays, as well as handling emergencies.

- Interconnection to the fire alarm system: In case of fire alarm, the fire alarm panel will self-test the signal and confirm that there is a fire, then the official signal will be sent to the management system. To get in and open all doors in the rooms (to prevent the crooks taking advantage of the fire alarm to open the door, the entrance control system can receive fire alarms in the area where the fire alarm system is available. Access levels and access control systems will only open doors in that area.)

The equipment must comply with standards ISO, FCC, CE, origin Korea, Hong Kong, Singapore, Japan, USA ...

Solution

Evaluation of the owner

The security control system combined with timekeeping is evaluated by the owner

Photo realistic

Hình ảnh hệ thống cửa anh ninh tripod (05 Lanes) kiểm soát vào ra và chấm công


The installation of ACS-IDTECK / Korea equipment details on the Tripod Turnstile control access and time attendance